Ultimate Screw Remover Kit
Ultimate Screw Removal Kit
The ultimate screw remover kit is used for the removal of stripped and fractured prosthetic screws. Included in the kit are two sets of remover drills, reverse drills, and tap drills which are used to remove fractured screws. A flat tip driver is also included to remove stripped screws. Guides are provided which help to center the drills and taps, ensuring that the internal threads of the implant are not damaged. This versatility of the ultimate screw remover kit makes it an essential addition to any implant practice.
Screw Removal Components
- Prosthetic guide holder
- Long ratchet wrench
- Adapter (contra Angle to 4mm square)
- Reverse drills
- Reverse tap
- Flat tip driver
- Prosthetic guides (listed below)
External Mini (M)
- Hi-Tec Summit®
- Nobel Biocare Branemark® System NP
Octa Internal (O)
- Hi-Tec Tite-Fit & Tapered Tite-Fit®
- Straumann ITI Tissue Level®
- Implant Direct SwishPlant®
TSV 3.7/4.1
- Hi-Tec Logic+, Spark, Self-Thread®
- BioHorizons Tapered Internal®3.7 and 4.7
- Implant Direct Legacy® (3.7 and 4.7 internal hex)
- MIS® 3.3, 3.75, and 4.2
- Zimmer TSV® 3.7, 4.1 and 4.7
External Regular (W)
- Nobel Biocare Branemark® System RP 4.1
Hex Submerged (H)
- Hi-Tec Logic, Implex, Expert NL®
- Nobel Biocare NobelActive®
Trilobe 3.5 NP
- Hi-Tec Vision 3.5
- Nobel Biocare Tri Lobe 3.5
Instructions for Stripped Screw Removal
Stripped screws are generally more difficult to remove than fractured screws because fractured screws are not under compression. The most effective method of removing a stripped screw is to create a flathead channel with a round bur, and then use a flat head driver to reverse the screw out of position
Step 1: Using a 1/2 round bur in a high-speed handpiece, create a channel on the head of the screw across the diameter of the head, creating a flat head
Step 2: After the channel is created, use the FTD-01 and ratchet wrench to back the screw out
Instructions for Fractured Screw Removal
Step 1: Press the remover drill (D-REM) in the reverse direction (under 80rpm) on the top of the fractured screw to reverse the screw fragment out of the screw channel
Step 2: If the remover drill is unsuccessful: Use the provided guide information to select the correct prosthetic guide based on the implant platform
Step 3: Attach the selected guide to the guide handle and engage the connection within the implant
Step 4: With your handpiece in reverse (1,200-1,300 rpm); create a divot in the top of the screw with the D-REM
Step 5: Remove Prosthetic Guide
Step 6: With your handpiece in reverse (under 80rpm) press the tap into the screw channel to engage the screw
Summary
Ultimate Screw Removal Kit
The ultimate screw remover kit is used for the removal of stripped and fractured prosthetic screws. Included in the kit are two sets of remover drills, reverse drills, and tap drills which are used to remove fractured screws. A flat tip driver is also included to remove stripped screws. Guides are provided which help to center the drills and taps, ensuring that the internal threads of the implant are not damaged. This versatility of the ultimate screw remover kit makes it an essential addition to any implant practice.
Screw Removal Components
- Prosthetic guide holder
- Long ratchet wrench
- Adapter (contra Angle to 4mm square)
- Reverse drills
- Reverse tap
- Flat tip driver
- Prosthetic guides (listed below)
External Mini (M)
- Hi-Tec Summit®
- Nobel Biocare Branemark® System NP
Octa Internal (O)
- Hi-Tec Tite-Fit & Tapered Tite-Fit®
- Straumann ITI Tissue Level®
- Implant Direct SwishPlant®
TSV 3.7/4.1
- Hi-Tec Logic+, Spark, Self-Thread®
- BioHorizons Tapered Internal®3.7 and 4.7
- Implant Direct Legacy® (3.7 and 4.7 internal hex)
- MIS® 3.3, 3.75, and 4.2
- Zimmer TSV® 3.7, 4.1 and 4.7
External Regular (W)
- Nobel Biocare Branemark® System RP 4.1
Hex Submerged (H)
- Hi-Tec Logic, Implex, Expert NL®
- Nobel Biocare NobelActive®
Trilobe 3.5 NP
- Hi-Tec Vision 3.5
- Nobel Biocare Tri Lobe 3.5